Problems of maintainability of the equipment of aic on the example of statistical researches the wear of the rotor type pump
Keywords:
*
Abstract
The paper presents results of experiments according to wear and identification of failure causes of the pump NR-10. It is established that covers surfaces of the working chamber, conducting and conducted shaft of the rotor pump are the main working surfaces defining change of working pressure of the pump. We received here the qualitative picture of surfaces wear and quantitative characteristics of wear distribution.